C and R Testing logo
C & R TESTING LIMITED

Air-Care

Here at C & R Testing we provide air care to the HSE Standards below. Please contact us for further details of air care and costs involved.

The current HSE Standards for breathing air for use by sport divers are EN12021.

The following table gives the maximum allowable levels of contamintion.

Contaminant Maximum allowable to BS EN12021
Oxygen content (21 ±1)% by volume (dry air).
Carbon Monoxide content shall be as low as
possible but not exceed 15 ml.m-3 (15 ppm).
Carbon Dioxide content shall not exceed 500 ml.m-3 (500 ppm).
Lubricant content (droplets or mist) shall not exceed 0.5 mg.m-3.
Water There shall be no free liquid water.
The maximum water content of the air
measured at:
  • a compressor system outlet for filling cylinders,
    should not exceed 25 mg.m-3;
  • a cylinder outlet, cylinder pressure from 40 to
    200 bar, should not exceed 50 mg.m-3;
  • a cylinder outlet, cylinder pressure >200 bar,
    should not exceed 35 mg.m-3.
Other Contaminants 5ppm
Odour and Taste The air shall be without significant odour or taste.
Clenliness No dust, dirt, metallic particles, toxic or irritatating ingredients

Air testing should be done approximately every three months.


C & R Testing Ltd.
Evans Business Centre, Dane Street, Rochdale. OL12 6XB
Tel: +44 161 408 2560, Email: candrtesting@btconnect.com